IPC-630 User Manual 26
4.3 Jumper Settings
4.4 Thermal Sensor
There is a thermal sensor near the left rear of the chassis. Please refer to Figure 4.2
to find the location.
Figure 4.2 Thermal sensor location
If the machine overheats, the temperature sensor will send a signal to the alarm
board and a continuous alarm will sound. To stop the alarm from beeping, press the
Alarm Reset button on the front panel.
Table 4.2: J2, PIC Clear jumper
Normal Open (default)
Clear Short
Table 4.3: J3, Thermal Sensor jumper
One sensor Open (default)
Disable Short
Table 4.4: J4, Fan Option jumper
One fan Open (default)
Two fans Short