JP13: Watchdog Timer Setting
The watchdog timer supervisory function will automatically reset USB-
4718 in the event of system failure. JP13 on USB-4718 can enable/dis-
able watchdog timer function or reset module manually.
How to Reset USB-4718 Manually
Plug the jumper to JP13 pin2-3 and then remove it, USB-4718 will reset.
Note:
Users may restart the application programs after USB-4718 is reset.