Advantech PCI-1731 Specifiche Pagina 18

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 60
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 17
Chapter 2
PCI-1711/1731 Users Manual
Advantech Co., Ltd.
www.advantech.com
– 14 –
Fig. 2-8 The “Device(s) Found” dialog box
Configuring the Device
Step 5: On the Device Setting dialog box (Fig. 2-9), you can configure
the voltage source either as External or Internal, and specify
the voltage output range for the 2 D/A channels.
Fig. 2-9 The Device Setting dialog box
Note:
Users can configure the source of D/A reference voltage either as
Internal or External, and select the output voltage range. When
selecting voltage source as Internal, users have two options for the
output voltage range : 0 ~ 5V and 0 ~ 10V.
When selected as External, the output voltage range is determined by
the external reference voltage in the following way :
By inputting an external reference voltage: -xV , where |x| <= 10,
you will get a output voltage range: 0 to xV.
Vedere la pagina 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 59 60

Commenti su questo manuale

Nessun commento