3-35
Isolation Voltage 3000 V
DC
Fault and over-voltage protection Withstands over voltage up to ±35 V
Sampling Rate 10 sample/sec (total)
Input Impedance Voltage: 20 M, Current: 120
Accuracy ±0.1% or better
Power Consumption 0.8 W @ 24V
DC
I/O Connector Type 10 pin plug-in terminal
Table 3-4 Technical specification of ADAM-4018+
Application Wiring
Figure 3-30 Current Input Wiring Diagram of ADAM-4017
Vin0-
Vin0+
11
V
-
+
mV/V
Figure 3-31(a) ADAM-4017 Differential Input Wiring Diagram (Ch0 ~ Ch5)